Fluke 750P01 25mbar Pressure Module

A complete family of precision pressure modules

  • Covers workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar)
  • 8 intrinsically safe models for use with Fluke 718EX or 725EX
  • Reduce errors by digitally sending measurements to calibrators
  • Precision measurements with reference uncertainties up to 0.01%

Features

Fluke 750P Series Pressure Modules will turn your Fluke multifunction calibrator into a full-fledged pressure calibrator. These flexible modules not only work with multifunction calibrators like the 725, 726 or 750 Series Calibrators but also extend the measurement range of Fluke pressure calibrators. Since the pressure modules are calibrated independently, they can be swapped from one calibrator to another without a loss of accuracy or traceability.

Measuring pressure with Fluke 750P Series Pressure modules is as easy as connecting the module to a pressure source or hand pump, connecting the pressure module cable to the calibrator and then applying pressure from the pressure source. At the touch of a button the measured pressure is displayed digitally on the calibrator in up to 11 different engineering units quickly giving you the data you need. And, with “no tools required” connectors you don’t even need to reach for a wrench to make connections.

When used with the 750 Series Documenting Process Calibrators pressure readings can even be date/time stamped and stored in documented calibration records for later retrieval. This saves time, eliminates errors, and supports compliance with quality standards and regulations.

A complete family of pressure modules
With over 50 pressure modules covering pressure calibration and measurement workloads from 1 inH20 to 10,000 psi (2.5 mBar to 690 bar) finding a model to meet the needs of your specific application is easier than ever. All modules include NPT, metric (BSP) and M20 adapters.

Choose from:

Differential modules
Gage modules
High pressure modules
Absolute modules
Vacuum modules
Dual range modules
Reference modules
Intrinsically safe modules
With more than 50 pressure modules to choose from, some of the more popular modules include:

Fluke 750P00
Fluke 750P02
Fluke 750PD2
Fluke 750P03
Fluke 750P05
Fluke 750P06
Fluke 750P29
Click the Models tab above for a full list of pressure modules.

Designed to go where you work
Pressure instruments are often installed in harsh, hard to reach locations, so you need test tools that handle rough service. 750P Series Pressure Modules feature a rugged protective boot that guards the module against shock and seals against dirt and dust, if you accidently drop them, there’s no need to worry. The 750P series modules are also specified across a broad temperature range. Though more accurate across a narrower temperature range if used indoors, these modules are designed and specified to deliver traceable pressure measurements in environments from -10 °C to +50 °C.

Product Details

Specifications: Fluke 750P Series Pressure Modules
Differential Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P00 0 to 1 inH2O (0 to 2.5 mBar) 30X Dry air Dry air
750P3IN 0 to 3 Inch H2O (0 to 7.5 mbar) 10X Dry air Dry air
750P5IN 0 to 5 Inch H2O (0 to 12.5 mbar) 6X Dry air Dry air
750P017 0 to 10 inH2O (0 to 25 mBar) 3X Dry air Dry air
750P02 0 to 1 psi (0 to 70 mBar) 3X Dry air Dry air
750P22 0 to 1 psi (0 to 70 mBar) 3X 316 SS Dry air
750P03 0 to 5 psi (0 to 350 mBar) 3X Dry air Dry air
750P23 0 to 5 psi (0 to 350 mBar) 4X 316 SS Dry air
750P04 0 to 15 psi (0 to 1 bar) 3X Dry air Dry air
750P247 0 to 15 psi (0 to 1 bar) 4X 316 SS Dry air
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750P00 ±0.15% ±0.3% ±0.35% ±0.25% ±0.30%
750P3IN ±0.15% ±0.3% ±0.35% ±0.25% ±0.30%
750P5IN ±0.15% ±0.3% ±0.35% ±0.25% ±0.30%
750P017 ±0.1% ±0.2% ±0.3% ±0.15% ±0.25%
750P02 ±0.050% ±0.1% ±0.15% ±0.075% ±0.125%
750P22 ±0.050% ±0.1% ±0.15% ±0.075% ±0.125%
750P03 ±0.02% ±0.04% ±0.05% ±0.035% ±0.04%
750P23 ±0.02% ±0.04% ±0.05% ±0.035% ±0.04%
750P04 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P247 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
Gage Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P057 0 to 30 psi (0 to 2 bar) 4X 316 SS N/A
750P067 0 to 100 psi (0 to 7 bar) 4X 316 SS N/A
750P277 0 to 300 psi (0 to 20 bar) 4X 316 SS N/A
750P07 0 to 500 psi (0 to 35 bar) 4X 316 SS N/A
750P08 0 to 1000 psi (0 to 70 bar) 3X 316 SS N/A
750P097 0 to 1500 psi (0 to 100 bar) 3X 316 SS N/A
750P2000 0 to 2000 psi (0 to 140 bar) 3X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750P057 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P067 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P277 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P07 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P08 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P097 ±0.0175% ±0.035% ± 0.045% ±0.03% ±0.04%
750P2000 ±0.0175% ±0.035% ± 0.045% ±0.03% ±0.04%
High Pressure Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750P29 0 to 3000 psi (0 to 200 bar) 3X 316 SS N/A
750P30 0 to 5000 psi (0 to 340 bar) 3X 316 SS N/A
750P31 0 to 10000 psi (0 to 700 bar) 2X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750P29 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P30 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
750P31 ±0.0175% ±0.035% ±0.045% ±0.03% ±0.04%
Absolute Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PA3 0 to 5 psia (0 to 350 mBar) 4X 316 SS N/A
750PA47 0 to 15 psia (0 to 1 bar) 4X 316 SS N/A
750PA5 0 to 30 psia (0 to 2 bar) 4X 316 SS N/A
750PA6 0 to 100 psia (0 to 7 bar) 4X 316 SS N/A
750PA27 0 to 300 psia (0 to 20 bar) 4X 316 SS N/A
750PA7 0 to 500 psia (0 to 35 bar) 4X 316 SS N/A
750PA8 0 to 1000 psia (0 to 70 bar) 3X 316 SS N/A
750PA9 0 to 1500 psia (0 to 100 bar) 3X 316 SS N/A
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750PA3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA47 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA5 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA6 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA27 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA7 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA8 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PA9 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
Vacuum Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PV3 -5 psi (-350 mBar) 4X 316 SS Dry air
750PV4 -15 psi (-1 bar) 4X 316 SS Dry air
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750PV3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PV4 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
Dual Range Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750PD2 -1 to 1 psi (-70 to 70 mBar) 4X 316 SS Dry air
750PD3 -5 to 5 psi (-350 to 350 mBar) 4X 316 SS Dry air
750PD10 -10 to 10 psi (-700 to 700 mBar) 4X 316 SS Dry air
750PD4 -15 to 15 psi (-1 to 1 bar) 4X 316 SS Dry air
750PD5 -15 to 30 psi (-1 to 2 bar) 4X 316 SS —
750PD50 -15 to 50 psi (-1 to 3.5 bar) 4X 316 SS —
750PD6 -15 to 100 psi (-1 to 7 bar) 4X 316 SS —
750PD7 -15 to 200 psi (-1 to 14 bar) 4X 316 SS —
750PD27 -15 to 300 psi (-1 to 20 bar) 4X 316 SS —
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750PD2 ±0.05% ±0.1% ±0.15% ±0.075% ±0.125%
750PD3 ±0.03% ±0.06% ±0.07% ±0.05% ±0.06%
750PD10 ±0.025% ±0.05% ±0.07% ±0.04% ±0.06%
750PD4 ±0.0175% ±0.035% ±0.045% ±0.03% ± 0.04%
750PD5 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD50 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD6 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD7 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
750PD27 ± 0.0175% ± 0.035% ± 0.045% ±0.03% ± 0.04%
Reference Module Specifications
Model Parameter / range Burst rating6 Hi side media2 Lo side media2
750R045 0 to 15 psi (0 to 1 bar) 3X Dry air Dry air
750R065 0 to 100 psi (0 to 7 bar) 4X 316 SS —
750R27 0 to 300 psi (0 to 20 bar) 4X 316 SS —
750R07 0 to 500 psi (0 to 35 bar) 4X 316 SS —
750R085 0 to 1000 psi (0 to 70 bar) 3X 316 SS —
750R29 0 to 3000 psi (0 to 200 bar) 3X 316 SS —
750R30 0 to 5000 psi (0 to 340 bar) 3X 316 SS —
750R315 0 to 10000 psi (0 to 700 bar) 2X 316 SS —
750RD5 -15 to 30 psi (-1 to 2 bar) 4X Dry air —
750RD65 -12 to 100 psi (-0.8 to 7 bar) 4X 316 SS —
750RD27 -12 to 300 psi (-0.8 to 20 bar) 4X 316 SS —
Model Reference uncertainty4 Total uncertainty
1-year
(15-35°C) Total uncertainty
1-year1 Total uncertainty
6-month
(15-35°C) Total uncertainty
6-month1
750R045 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R065 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R27 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R07 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R085 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R29 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R30 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R315 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD5 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD65 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750RD27 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
1. Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one year interval. No 6 month specification available for range -10°C to 0°C.
2. “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel.
3. Specifications % of Full Span unless otherwise noted.
4. Reference Uncertainty is the specification for as left data for 24 hours.
5. When reference class modules are used with fixed resolution products (717, 718, 719 series, 725 and 726) calibrators add ±1 count to the overall accuracy specification.
6. Burst rating specification refers to the multiplier times full scale of the module for the rated burst pressure.
7. Intrinsically Safe pressure module available in this pressure range.

    Downloads

    Committing to 3, 6 or 12 Months?

    Call us for fantastic long term hire rates.

    Contact Us

    NEED TECHNICAL SUPPORT?

    Call us for fantastic long term hire rates.

    Tech Support

    The Powertech Difference

    • Huge inventory of test and measurement equipment
    • Calibration labs for Electrical, Pressure, Torque, Temperature, Flow, Dimensional and PPE
    • Remote support when you need it
    • 24/7 end to end online web shop
    • If we don’t have the equipment you are looking for – we will find it for you!

    Speak to our experts today