Fluke i2000 2000A 1mV/A AC Flexi Current Clamp

The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.

Features

  • Three ranges: 20A, 200 A & 2000 A, 100 mV/A, 10 mV/A & 1 mV/A output
  • Ideal for current measurement on thick and hard to reach conductors without breaking the circuit
  • Maximum conductor diameter 178 mm
  • CAT III 600 V safety rating

Product Details

  • Specifications: Fluke i2000 Flex AC Current Clamp
  • Electrical specifications
  • Current ranges 20 A
  • 200 A
  • 2000 A
  • AC rms
  • Output sensitivity (AC-coupled) 1 mV
  • 10 mV
  • 100 mV
  • 1 mV per A
  • Load impedance 100 k? minimum
  • Accuracy at +25°C
  • ±1% of range (45 Hz to 65 Hz)
  • Linearity 10% to 100% of range
  • ±0.2% of reading
  • Noise 8 mV AC rms (30 A)
  • 2 mV AC rms (300 A, 3000 A)
  • Frequency range 10 Hz to 20 kHz (-3 dB)
  • Phase error < ±1° (45 Hz to 65 Hz) ±10° (at 20 kHz) Position sensitivity (with cable > 25 mm from the coupling)
  • Position sensitivity: From 1% up to 3% of range with cable, depending on distance from the center (see figure left). Measurements closer than 25 mm from the coupling are typically greater than 3% of range.
  • External wire influence: 1% (-40 db) of external current >200 mm from head.
  • External field with cable > 200 mm from the head
  • ±1% of range
  • Power supply 2 x AA/MN 1500/LR6 Alkaline, 200 hours, low battery indicator
  • Temperature Coefficient ±0.08% of reading per °C
  • Working voltage see Safety standards section
  • 600 V AC rms or DC
  • General Specifications
  • Head Circumference 610 mm (24 in)
  • Head cable diameter 14.3 mm (0.56 in)
  • Head bend radius 38.1 mm (1.5 in)
  • Cable length (head to electronics) 2 m (6.56 ft)
  • Output connection Molded 4 mm safety plugs (not integrated)
  • Operating temperature range 0°C to +70°C (32°F to 158°F) (head and electronics)
  • Storage temperature range -40°C to +105°C (-40°F to 221°F) (head)
  • -20°C to +85°C (-4°F to 185°F) (electronics)
  • Operating humidity 15% to 85% (non-condensing)
  • Weight 180 g (6.34 oz) (head)
  • 190 g (6.70 oz) (electronics)
  • Safety standards EN 61010-031: 2002
  • EN 61010-2-032: 2002
  • EN 61010-1: 2001
  • 600 Vrms, Category III, Pollution Degree 2
  • Use of the probe on uninsulated conductors is limited to 600 V ac rms or dc and frequencies below 1 kHz.
  • EMC standards EN 61326: 1998 +A1, A2, and A3
  • Dimensions (H x W x D) 116 x 68.5 x 30 mm (4.56 x 2.69 x 1.18 in)

 

    Downloads

    Committing to 3, 6 or 12 Months?

    Call us for fantastic long term hire rates.

    Contact Us

    NEED TECHNICAL SUPPORT?

    Call us for fantastic long term hire rates.

    Tech Support

    The Powertech Difference

    • Huge inventory of test and measurement equipment
    • Calibration labs for Electrical, Pressure, Torque, Temperature, Flow, Dimensional and PPE
    • Remote support when you need it
    • 24/7 end to end online web shop
    • If we don’t have the equipment you are looking for – we will find it for you!

    Speak to our experts today