Fluke 1587 1kV Insulation Multimeter

The Fluke 1587 Insulation Multimeter is the single tool that allows users to perform advanced insulation testing for preventive and PdM tasks. Combining a digital insulation tester with a full-featured, true-rms digital multimeter into a compact, hand-held unit, the 1587 model provides maximum versatility for both troubleshooting and preventative maintenance.

Features

  • Safety first. Connect the insulation tester then keep yourself out of harm’s way by monitoring your test measurements remotely.
  • Prove your job is done right by quickly seeing and sharing insulation resistance test results wirelessly with your smartphone.
  • Quickly find problems by saving and comparing measurements over time on a wireless device.

Product Details

  • Specifications: Fluke 1587 FC Insulation Multimeter
  • Electrical Specifications
  • AC voltage measurement
  • Range
  • 0 mV Resolution 0.1 mV
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
  • 000 V Resolution 0.001 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
  • 00 V Resolution 0.01 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)
  • 0 V Resolution 0.1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
  • 1000 V Resolution 1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
  • Accuracy 60 Hz to 5000 Hz ±(% of Rdg + Counts) ±(2% + 3)¹
  • ¹ 1 kHz bandwidth
  • Low-Pass Filter Voltage
  • Range
  • 0 mV Resolution 0.1 mV
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
  • 000 V Resolution 0.001 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
  • 00 V Resolution 0.01 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
  • 0 V Resolution 0.1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(1% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
  • 1000 V Resolution 1 V
  • Accuracy 50 Hz to 60 Hz ±(% of Rdg + Counts) ±(2% + 3)
  • Accuracy 60 Hz to 400 Hz ±(% of Rdg + Counts) +(2% + 3), -(6% – 3)
  • DC Voltage Measurement
  • Range Resolution Accuracy ±(% of Rdg + Counts)
  • 000 V dc 0.001 V ±(0.09% + 2)
  • 00 V dc 0.01 V ±(0.09% + 2)
  • 0 V dc 0.1 V ±(0.09% + 2)
  • 1000 V dc 1 V ±(0.09% + 2)
  • Input impedance 10 M? (nominal), <100 pF Normal mode rejection ratio >60 dB @ 50 Hz or 60 Hz
  • Common mode rejection ratio >120 dB @ dc, 50 Hz or 60 Hz (1 k unbalance)
  • Accuracies apply to ± 100% of range
  • DC Millivolts Measurement
  • Range Resolution Accuracy ±(% of Rdg + Counts)
  • 0 mVdc 0.1 mV ±(0.1% + 1)
  • DC and AC Current Measurement
  • AC 45 Hz to 1000 Hz
  • Range 400 mA
  • Resolution 0.1 mA
  • Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
  • Burden voltage (Typical) 2 mV/mA
  • Range 60 mA
  • Resolution 0.01 mA
  • Accuracy ±(% of Rdg+Counts) ±(1.5% + 2)¹
  • Burden voltage (Typical) 2 mV/mA
  • DC
  • Range 400 mA
  • Resolution 0.1 mA
  • Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
  • Burden voltage (Typical) 2 mV/mA
  • Range 60 mA
  • Resolution 0.01 mA
  • Accuracy ±(% of Rdg+Counts) ±(0.2% + 2)
  • Burden voltage (Typical) 2 mV/mA
  • Overload 600 mA for 2 minutes maximum
  • Fuse protection for mA input 0.44 mA, 1000 V, IR 10 kA
  • AC conversion Inputs are ac-coupled and calibrated to the rms value of sine wave input
  • Conversions are true-rms responding and specified from 5% to 100% of range. Input signal crest factor can be up to 3 up to 300 mA, decreasing linearly to crest factor ?1.5 at 600 mA. For non-sinusoidal waveforms add +(2% reading + 2% FS) typical, for a crest factor up to 3.
  • ¹ 1 kHz bandwidth
  • Ohms Measurement
  • Range Resolution Accuracy +(% of Rdg+Counts)¹
  • 0 ? 0.1 ? ±(0.9% + 2)
  • 000 k? 0.001 k? ±(0.9% + 2)
  • 00 k? 0.01 k? ±(0.9% + 2)
  • 0 k? 0.1 K? ±(0.9% + 2)
  • 000 M? 0.001 M? ±(0.9% + 2)
  • 0 M? ² 0.01 M? ±(1.5% + 3)
  • Overload protection 1000 V rms or dc
  • Open circuit test voltage <8.0 V dc
  • Short circuit current <1.1 mA
  • ¹ Accuracies apply from 0% to 100% of range
  • ² Up to 80% relative humidity
  • Diode Test
  • Diode test indication Display voltage drop: 0.6 V at1.0 mA nominal test current:
  • Accuracy ±(2% + 3)
  • Continuity Test
  • Continuity indication Continuous audible tone for testresistance below 25 ? and off above 100 ?. Maximum Reading; 1000 ?
  • Open circuit voltage <8.0 V Short circuit current 1.0 mA typical Overload protection 1000 V rms Response time >1 m sec
  • Frequency Measurement
  • Range Resolution Accuracy ±(% of Rdg+Counts)
  • 99 Hz 0.01 Hz ±(0.1% + 1)
  • 9 Hz 0.1 Hz ±(0.1% + 1)
  • 999 kHz 0.001 kHz ±(0.1% + 1)
  • 99 kHz 0.01 kHz ±(0.1% + 1)
  • Frequency Counter Sensitivity
  • 0 mV ac V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 mV
  • V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 150.0 mV
  • DC Trigger Levels¹ to 20 kHz² NA
  • 0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 1.0 V
  • V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 1.5 V
  • DC Trigger Levels¹ to 20 kHz² -400.0 mV and 2.5 V
  • 0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 10.0 V
  • V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz 36.0 V
  • DC Trigger Levels¹ to 20 kHz² 1.2 V and 4.0 V
  • 0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 100.0 V
  • V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz –
  • DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
  • 0 V V ac Sensitivity (RMS Sine Wave)¹ 5 Hz to 20 kHz 300.0 V
  • V ac Sensitivity (RMS Sine Wave)¹ 20 kHz to 100 kHz –
  • DC Trigger Levels¹ to 20 kHz² 12.0 V and 40.0 V
  • ¹ Maximum input for specified accuracy = 10x range (1000 V max). Noise at low frequencies and amplitudes may affect accuracy
  • ² Usable to 100 kHz with full scale input
  • Capacitance
  • Range Resolution Accuracy ±(% of Rdg+Counts)
  • 1000 nF 1 nF ±(1.2% + 2)
  • 00 ?F 0.01 ?F ±(1.2% + 2)
  • 0 ?F 0.1 ?F ±(1.2% ±90 counts)
  • 9999 ?F 1 ?F ±(1.2% ±90 counts)
  • Temperature Measurement
  • Range Resolution Accuracy ±(% of Rdg+Counts)¹
  • -40 ° C to 537 ° C 0.1 °C ±(1% + 10 counts)
  • -40 ° F to 998 ° F 0.1 °F ±(1% + 18 counts)
  • ¹ Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
  • Insulation Specifications
  • Measurement range 0.01 M? to 2 G?
  • Test voltages 50, 100, 250, 500, 1000 V
  • Test voltage accuracy +20%, -0%
  • Short-circuit test current 1 mA nominal
  • Auto discharge Discharge time <0.5 second for C = 1 ?F or less Live circuit detection Inhibit test if terminal voltage > 30 V prior to initialization of test
  • Maximum capacitive load Operable with up to 1 ?F load
  • Output Voltage
  • 50 V (0% to +20%) Display range 0.01 to 6.00 M?
  • Resolution 0.01 M?
  • Test current 1 mA @ 50 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
  • Display range 6.0 to 50.0 M?
  • Resolution 0.1 M?
  • Test current 1 mA @ 50 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
  • 100 V (0% to +20%) Display range 0.01 to 6.00 M?
  • Resolution 0.01 M?
  • Test current 1 mA @ 100 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
  • Display range 6.0 to 60.0 M?
  • Resolution 0.1 M?
  • Test current 1 mA @ 100 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
  • Display range 60 to 100 M?
  • Resolution 1 M?
  • Test current 1 mA @ 100 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(3% + 5 counts)
  • 250 V (0% to +20%) Display range 0.1 to 60.0 M?
  • Resolution 0.1 M?
  • Test current 1 mA @ 250 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • Display range 60 to 250 M?
  • Resolution 1 M?
  • Test current 1 mA @ 250 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • 500 V (0% to +20%) Display range 0.1 to 60.0 M?
  • Resolution 0.1 M?
  • Test current 1 mA @ 500 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • Display range 60 to 500 M?
  • Resolution 1 M?
  • Test current 1 mA @ 500 k?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • 1000 V (0% to +20%) Display range 0.1 to 60.0 M?
  • Resolution 0.1 M?
  • Test current 1 mA @ 1 M?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • Display range 60 to 600 M?
  • Resolution 1 M?
  • Test current 1 mA @ 1 M?
  • Resistance accuracy ±(% of Rdg + Counts) ±(1.5% + 5 counts)
  • Display range 0.6 to 2.0 G?
  • Resolution 100 M?
  • Test current 1 mA @ 1 M?
  • Resistance accuracy ±(% of Rdg + Counts) ±(10% + 3 counts)
  • General Specifications
  • Maximum voltage applied to any terminal and common 1000 V
  • Storage temperature -40 °C to 60 °C (-40 °F to 140 °F)
  • Operating temperature -20 °C to 55 °C (-4 °F to 131 °F)
  • Temperature coefficient 0.05 x (specified accuracy) per °C for temperatures <18 °C or >28 °C (<64 °F or >82 °F)
  • Relative humidity Noncondensing
  • 0% to 95% @ 10 °C to 30 °C (50 °F to 86 °F)
  • 0% to 75% @ 30 °C to 40 °C (86 °F to 104 °F)
  • 0% to 40% @ 40 °C to 55 °C (104 °F to 131 °F)
  • Vibration Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument
  • Radio frequency communication 2.4 GHz ISM Band
  • Radio frequency certification FCC: T68-FBLE, IC: 6627A-FBLE
  • Electromagnetic Compatibility
  • International IEC 61326-1:Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A
  • Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.
  • Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances.
  • Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object. The equipment may not meet the immunity requirements of this standard when test leads and/or test probes are connected.
  • Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)
  • Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.
  • USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.
  • Enclosure protection IEC 60529: IP40 (non-operating)
  • Safety
  • IEC 61010-1 Pollution Degree 2
  • IEC 61010-2-033 CAT IV 600 V / CAT III 1000 V
  • Batteries Four AA batteries (IEC LR6)
  • Battery life Meter use 1000 hours; Insulation test use: Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 M? with a duty cycle of 5 seconds on and 25 seconds off.
  • Size (H x W x L) 5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)
  • Weight 550 g (1.2 lb)
  • Altitude Operating 2000 m
  • Storage 12,000 m
  • Over-range capability 110% of range except for capacitance which is 100%
  • Frequency overload protection <107 V Hz
  • Fuse protection for mA input 0.44A, 1000 V, IR 10 kA

    Downloads

    Committing to 3, 6 or 12 Months?

    Call us for fantastic long term hire rates.

    Contact Us

    NEED TECHNICAL SUPPORT?

    Call us for fantastic long term hire rates.

    Tech Support

    The Powertech Difference

    • Huge inventory of test and measurement equipment
    • Calibration labs for Electrical, Pressure, Torque, Temperature, Flow, Dimensional and PPE
    • Remote support when you need it
    • 24/7 end to end online web shop
    • If we don’t have the equipment you are looking for – we will find it for you!

    Speak to our experts today